Fuji Machinery FW3200 fault codes
Flow wrappers · 51 published codes and alarms, each with its meaning, likely causes and the fixes the documentation describes. Also written as Formost Fuji FW3200, FW3200/B, FW3210, FW3210/B, FW 3200, Fuji FW-3200.
Independent resource, not affiliated with Fuji Machinery.
Common symptoms
- Motor thermal switch tripped · E04
- IPM self-protection indicates major power fault · E05
- Converter thermal switch tripped · E36
- Firmware v11: shutdown, CED relay opens, motor coasts · E37
- Self-sensing commutation startup error · E39
- Missing Drive Enable input signal · E43
- Auxiliary encoder state error · E61
- Autotune procedure failed · E66
- Inverter thermal switch tripped · E72
- DC link current exceeds rating · E74
- Alarm shown on touch panel · *******BRUSH ERROR
- Emergency stop/power supply off message · INVERT ERROR
All fault codes
Servo drive alarms (A.xx)
- A.02 · Parameter failure
- A.03 · Main circuit detection failure
- A.04 · Parameter out of range
- A.05 · Motor and servopack mismatch
- A.7A · Heat sink overheat
- A.10 · Over current
- A.30 · Regenerative trouble
- A.32 · Regenerative overload
- A.40 · Over voltage
- A.41 · Under voltage
- A.51 · Over speed
- A.71 · Instantaneous overload
- A.72 · Continuous overload
- A.73 · DB overload
- A.74 · Resistor overload
- A.81 · Encoder backup alarm
- A.82 · Encoder sumcheck alarm
- A.83 · Encoder battery alarm
- A.84 · Encoder absolute data alarm
- A.85 · Encoder over speed
- A.86 · Encoder over heat
- A.91 · Overload warning
- A.92 · Regenerative overload warning
- A.b1 · Velocity A/D trouble
- A.b2 · Torque A/D trouble
- A.C1 · Servo motor overrun
- A.C8 · Encoder clear trouble
- A.C9 · Encoder communication trouble
- A.CA · Encoder parameter NG
- A.Cb · Encoder echoback trouble
- A.d0 · Position deviation over
- A.F1 · Power supply trouble
E codes
F codes
Touch panel messages
- *******BRUSH ERROR · Unstable sealer thermocouple signal
- INVERT ERROR · Infeed conveyor inverter or motor error
- REGI-MARK/SENS. ERROR · Regi-marks not detected in set operation