What F7 means

Motor Overload.

Likely causes, ranked

  1. Internal electronic overload trip from excessive motor loadmost likely

Quick checks

  • Verify A084 (Boost Select) setting

    Expected: Setting correct

Fix

Reduce loadlockout

  1. Reduce load so output current does not exceed P033 (Motor OL Current)

Safety

Follow your site's lockout procedures before working on the machine. This page does not replace the manufacturer's service.

Related codes

  • F5 · OverVoltage
  • F38 · Phase U to Gnd
  • F48 · Params Defaulted
  • F71 · Net Loss
  • F81 · Comm Loss
  • A.02 · Parameter failure

Every Fuji Machinery FW3200 fault code

Help the next technician

Log what fixed it

Thirty seconds: what cleared this code on your machine? Reviewed before it reaches anyone.

Put this on every machine

A QR code on each machine, cited fixes from the manual and your own plant's history, and a weekly report for the line. Ask for a demo.

Questions

What does F7 mean on a Fuji Machinery FW3200?
Motor Overload.
What causes F7 on the Fuji Machinery FW3200?
Internal electronic overload trip from excessive motor load (most likely).
How do I fix F7 on the Fuji Machinery FW3200?
First check: Verify A084 (Boost Select) setting (expected: Setting correct). Reduce load: 1) Reduce load so output current does not exceed P033 (Motor OL Current) Lock out the machine first.